Reaction to fire classification up
to B-s1,d0
CE certified
EN14915:2013
100% natural
& biodegradable
Indoor &
outdoor applications
Thanks to the process in our autoclave, many types of timber and panels have been tested and awarded reaction to fire classification B-s1,d0, in accordance with the European standard EN 13501.
Type of wood | Density | Min. thickness | Ventilated cavity | Reaction to fire class |
ThermoWood® Spruce | 314-434 | 15-42 mm | 40 mm | B-s1,d0 |
ThermoWood® Ash | 590-680 | 15-42 mm | 40 mm | B-s1,d0 |
ThermoWood® Pine | 450-500 | 15-42 mm | 40 mm | B-s1,d0 |
ThermoWood® Ayous | 269-374 | 15-42 mm | 40 mm | B-s1,d0 |
ThermoWood® Ayous | 305-470 | 15 mm | 40 mm | B-s2,d0 /B-s3,d0 |
ThermoWood® Fraké | 410-730 | 15-42 mm | 40 mm | B-s1,d0 |
ThermoWood® Poplar | 350-500 | 15-42 mm | 40 mm | B-s2,d0 |
With a ventilated or non-ventilated air gap between product and substrate or with no air gap
According to classification: EN 13501-1:2018 and EN 13501-2:2020
According to test: EN 13823
Colour coating with Sherwin Williams
Type of wood | Density | Min. thickness | Ventilated cavity | Reaction to fire class |
Solid wood | 355-536 | 19 mm | 40 mm | B-s1,d0 |
ThermoWood® | 450-500 | 19 mm | 40 mm | B-s2,d0 |
Sherwin Williams SC1420 + EG1570 on wood treated with Burnblock®, certified B-s1,d0
Pre greying with Masquelack
Type of wood | Density | Min. thickness | Ventilated cavity | Reaction to fire class |
Solid wood | 355-536 | 19 mm | 40 mm | B-s1,d0 |
ThermoWood® | 450-500 | 19 mm | 40 mm | B-s2,d0 |
Masquelack on wood treated with Burnblock®, certified B-s1,d0
Wood protector met SIOO:X
Type of wood | Density | Min. thickness | Ventilated cavity | Reaction to fire class |
Solid wood | 355-536 | 19 mm | 40 mm | B-s1,d0 |
ThermoWood® | 450-500 | 19 mm | 40 mm | B-s2,d0 |
Sioo:X Wood Protector + Sioo:X Surface Protector on Burnblock® B,s1-d0 certified wood
Except: ThermoWood® poplar (B-s2,d0)
To limit or delay the spreading of fires via the wooden facade, the Royal Decree imposes various requirements with regard to the reaction to fire of wooden facade cladding in its end-use conditions (in other words, as present on site).
This means that when assessing the reaction to fire of the wooden facade cladding, one must take into account the potential influence of the underlying material layers and the way in which they are fastened.
With LDCwood®, we can give timber products a fire retardant treatment with Burnblock® in our autoclave under pressure. At our production site in Ostend, both our autoclave and the drying killns guarantee a qualitative treatment in accordance with current standards.
With LDCwood®, we can give timber products a fire retardant treatment with Burnblock® in our autoclave under pressure. At our production site in Ostend, both our autoclave and the drying killns guarantee a qualitative treatment in accordance with current standards.
In accordance with Regulation 305/2011/EU of the European Parliament and the Council dated 9 March 2011 (the Construction Product Regulation or CPR), this certificate applies to the following construction product: wall and facade cladding of solid wood treated with fire retardant.
Burnblock®
Burnblock® is a 100% natural fire retardant for wood. It is effective on all absorbent materials such as timber and panels and has been certified to the highest European standards.
Burnblock®
Burnblock® is a 100% natural fire retardant for wood. It is effective on all absorbent materials such as timber and panels and has been certified to the highest European standards.
Protected by nature
+32 (0)59 50 55 14
protectedbynature@ldcwood.com
Vergunningenstraat 7, 8400 Ostend, Belgium
Stay on top of our products